-40%
IFM Efector control monitor for flow sensors SR5906 SRM12XXAKOW/LS-100-IRF
$ 94.51
- Description
- Size Guide
Description
IFM EfectorSR5906 SRM12XXAKOW/LS-100-IRF
control monitor for flow sensors.
Reliable monitoring of liquids and gases in pipes
For the connection of flow sensors with large immersion depths
For sensors made of ceramics, high-grade stainless steel and titanium
Easy setting of the switch points for quick set-up
LED bar graph for indication of switch point and flow
Flow monitor ifm efector SR5906
The SR5906 flow monitor from ifm with a programmable output as normally open or normally closed measures liquid and gaseous media via a selectable flow probe. Operates on 85-265 V AC. The SR5906 flow monitor can easily be integrated in the application by attaching directly to the flow probe, or via a patch cable. By means of the common 5-pole micro AC connector. The SR5906 flow sensor can be reliably connected to any ifm SF 10mm probe.For use in conjunction with ifm flow probes
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 3.5; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10; Number of channels : 1; Electrical design : relay; Contact rating : 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open); Switching cycles (mechanical) : 20_Millionen; Switching function flow monitoring : output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed; Short-circuit protection : no; Overload protection : no; Adjustment of the switch point : pushbutton; Ambient temperature [°C] : -20...60; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass.
Application
Application
Flow monitoring; Wire break monitoring
Electrical data
Frequency AC [Hz]
47...63
Operating voltage tolerance [%]
-15...10
Operating voltage [V]
90...240 AC
Max. power consumption [VA]
3.5
Protection class
II
Reverse polarity protection
no
Power-on delay time [s]
10
Number of channels
1
Outputs
Electrical design
Relay
Contact rating
3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open)
Switching cycles (mechanical)
20_Millionen
Switching function flow monitoring
output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed
Short-circuit protection
no
Overload protection
no
Software / programming
Adjustment of the switch point
pushbuttons
Operating conditions
Ambient temperature [°C]
-20...60
Protection
IP 67; (with sensor attached)
Tests / approvals
EMC
EN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
10 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-6 HF conducted
10 V
Shock resistance
DIN IEC 68-2-27
30 g (6 ms)
Vibration resistance
DIN IEC 68-2-6
2 g (55...2000 Hz)
MTTF [years]
209
Mechanical data
Weight [g]
244.5
Material
stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Displays / operating elements
Display
Function
LED, bar graph
Switching status
LED, orange flash in case of wire break
Electrical connection
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting
Remarks
Remarks
connection for flow sensor without short-circuit protection / reverse polarity protection
The flow sensor must be directly connected to the control monitor.
A connection by means of extension cables is not allowed.
Recommendation Check the safe functioning of the unit after a short circuit.
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x 1/2"; coding: C
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SR5906-01 — 21.01.2022 —